Type H-2358 Sample Cells-Single Open Ended
|
Type H-2358 Sample Cells-Single Open Ended |
|
|
Overall Diameter With Flange |
48mm |
|
Overall Height |
18.5mm |
TECHREF® Type H-2358 Sample Cell are designed and manufactured specifically for use with the Carousel models of Horiba X-Ray Fluorescence Analyzers (newer than the SLFA-920), for the measurement of sulfur in various liquids. The Type H-2358 Sample Cell has an extension lip on the ring. This lip allows the membrane to be recessed. Horiba’s design of their carousel has the Sample Cell touching the analyzer floor when rotating. This new feature is designed to help prevent contamination from dust or debris when the Sample Cell is moving with the carousel unit leading to more accurate testing results. This lip also helps to prevent damage to the membrane during rotation. The Type H-2358 Sample Cell still allows close membrane-to-membrane fit with the 2nd membrane in the analyzer, providing better repeatability during low level analysis. TECHREF® Type H-2358 Sample Cells are Horiba tested and approved.
TECHREF® Type H-2358 Sample Cell may also be used in single-load Horiba X-Ray Fluorescence Analyzers newer than SLFA-920, including the new Horiba Mesa 6000 analyzer as well as single-load Sindie® X-Ray Fluorescence Analyzers.
TECHREF® Type H-2358 Sample Cells are packaged 48 per box in a re-closeable chipboard box. The Type H-2358 Sample Cells are sold by the box only.
TECHREF® Type H-2358 Sample Cells are protected by U.S. Patent No. 6,603,544.
TECHREF® Type H-2358 Sample Cells are manufactured by an injection-molding process from a virgin low-density polyethylene. Each Sample Cell consists of two parts: a closed-bottom cup plus an outer, open ring which holds and seals the desired film after sample is loaded. There are two fill lines in the interior of the cup for consistent sample size. Each ring, cup assembly has a mating locking line to help prevent leakage. For volatile samples, there is a dimple on the cup exterior floor for venting and a reservoir for overflow. The Sample Cell is designed to produce a flat, tight and wrinkle-free membrane with any customary XRF membrane film product, ours or others. The Type H-2358 Sample Cells are fully disposable. There is no need to disassemble them to recover reusable parts. They are designed to work well with the aluminum jig tool furnished by Horiba for Horiba analyzers.
Important Notes:
1. Handling of Sample Cells: Avoid touching the inside of the Sample Cell. Oil from fingerprints can affect the reading when analyzing for low levels of sulfur.
2. All XRF Sample Cells present the possibility of leakage, with potential damage to the analytical instrumentation. It is recommended that after the Sample Cell has been loaded with sample and assembled, check for any leaks. The use and application of this product is the sole responsibility of the user.
®TECHREF Logo is Registered Trademark of TECHREF, INC.